fix: standstill fan clamp 0-30% and bench mode always 30-100%
Some checks failed
prebuilt / build prebuilt (push) Has been cancelled
badges / create badges (push) Has been cancelled

Standstill quiet mode was clamped to 0-10% which is dangerously low
under sustained load. Raised to 0-30%. Bench mode now forces 30-100%
onroad fan range regardless of standstill to prevent overheating
during bench testing.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
This commit is contained in:
2026-04-15 03:09:41 +00:00
parent ffa9da2f97
commit b84c268b6e

View File

@@ -1,4 +1,5 @@
#!/usr/bin/env python3
import os
from abc import ABC, abstractmethod
from openpilot.common.realtime import DT_TRML
@@ -6,6 +7,8 @@ from openpilot.common.numpy_fast import interp
from openpilot.common.swaglog import cloudlog
from openpilot.selfdrive.controls.lib.pid import PIDController
BENCH_MODE = os.environ.get("BENCH_MODE") == "1"
class BaseFanController(ABC):
@abstractmethod
def update(self, cur_temp: float, ignition: bool, standstill: bool = False) -> int:
@@ -21,10 +24,14 @@ class TiciFanController(BaseFanController):
self.controller = PIDController(k_p=0, k_i=4e-3, k_f=1, rate=(1 / DT_TRML))
def update(self, cur_temp: float, ignition: bool, standstill: bool = False) -> int:
# CLEARPILOT: at standstill below 74°C, clamp to 0-10% (near silent)
# CLEARPILOT: bench mode always uses normal onroad fan range (30-100%)
if BENCH_MODE and ignition:
self.controller.neg_limit = -100
self.controller.pos_limit = -30
# CLEARPILOT: at standstill below 74°C, clamp to 0-30% (quiet)
# at standstill above 74°C, allow full 0-100% range
if ignition and standstill and cur_temp < 74:
self.controller.neg_limit = -10
elif ignition and standstill and cur_temp < 74:
self.controller.neg_limit = -30
self.controller.pos_limit = 0
elif ignition and standstill:
self.controller.neg_limit = -100